IMDG Code 42-24 · Dangerous Goods List

Open interactive lookup ↗

UN1259NICKEL CARBONYL

English proper shipping name · Check the cargo and applicable provisions before shipment.

Class6.1
Packing groupI
EmSF-E, S-D

Dangerous Goods List entries

The comparison below lists all entries. Expanded provisions and the label preview on this page apply to Entry 1.

Compare all 1 DGL entry

Entry 1 · Packing group I

NICKEL CARBONYL

Class
6.1
Subsidiary risk / reference
3
Packing group
I
Marine pollutant entry
P
Limited quantities
0
Excepted quantities
E0
Packing instruction
P601
Special provisions
Not listed
Special packing provision
Not listed
IBC instruction
Not listed
IBC special provisions
Not listed
Portable tank / bulk container codes
Not listed
Tank special provisions
Not listed
EmS
F-E, S-D
Stowage and handling
Category D SW2 Category D SW2
Segregation
SG63
Properties and observations · source text
Colourless or yellow, volatile, flammable liquid. Flashpoint: below 20 C c.c. Oxidizes in air and explodes at a - ° temperature of 60 C. Lower explosive limit: 2.0%. ° Immiscible with water. Highly toxic if swallowed, by skin contact or by inhalation.

Packing and large packaging instructions

P601

Source pages and references

Check original English pages and footnotes ↗ · official PDF 214–214

P601 The following packagings are authorized provided the general provisions of 4.1.1 and 4.1.3 are met and the packagings are hermetically sealed: (1) Combination packagings with a maximum gross mass of 15 kg, consisting of: (a) o ne or more glass inner packaging(s) with a maximum net quantity of 1 L each and filled to not more than 90% of their capacity; the closure(s) of which shall be physically held in place by any means capable of preventing back-off or loosening by impact or vibration during transport, individually placed in (b) m etal receptacles together with cushioning and absorbent material sufficient to absorb the entire contents of the glass inner packaging(s), further packed in (c) 1A1, 1A2, 1B1, 1B2, 1N1, 1N2, 1H1, 1H2, 1D, 1G, 4A, 4B, 4N, 4C1, 4C2, 4D, 4F, 4G or 4H2 outer packagings. (2) Combination packagings consisting of metal or plastics inner packagings not exceeding 5 L in capacity individually packed with absorbent material sufficient to absorb the contents and inert cushioning material in 1A1, 1A2, 1B1, 1B2, 1N1, 1N2, 1H1, 1H2, 1D, 1G, 4A, 4B, 4N, 4C1, 4C2, 4D, 4F, 4G or 4H2 outer packagings with a maximum gross mass of 75 kg. Inner packagings shall not be filled to more than 90% of their capacity. The closure of each inner packaging shall be physically held in place by any means capable of preventing back-off or loosening of the closure by impact or vibration during transport. (3) Packagings consisting of: Outer packagings: Steel or plastics drums, (1A1, 1A2, 1H1 or 1H2), tested in accordance with the test provisions in 6.1.5 at a mass corresponding to the mass of the assembled package either as a packaging intended to contain inner packagings, or as a single packaging intended to contain solids or liquids, and marked accordingly. Inner packagings: Drums and composite packagings (1A1, 1B1, 1N1, 1H1 or 6HA1), meeting the provisions of chapter 6.1 for single packagings, subject to the following conditions:.1 the hydraulic pressure test shall be conducted at a pressure of at least 3 bar (gauge pressure);.2 the design and production leakproofness tests shall be conducted at a test pressure of 0.30 bar;.3 they shall be isolated from the outer drum by the use of inert shock-mitigating cushioning material which surrounds the inner packaging on all sides;.4 their capacity shall not exceed 125 L;.5 closures shall be of a screw-cap type that are: (i) physically held in place by any means capable of preventing back-off or loosening of the closure by impact or vibration during transport; and (ii) provided with a cap seal..6 The outer and inner packagings shall be subjected periodically to a leakproofness test according to.2 at intervals of not more than two and a half years; and 4.7 The outer and inner packagings shall bear in clearly legible and durable characters: (i) the date (month, year) of the initial testing and the latest periodic test; (ii) the name or authorized symbol of the party performing the tests and inspections. (4) Pressure receptacles, provided that the general provisions of 4.1.3.6 are met. They shall be subjected to an initial test and periodic tests every 10 years at a pressure of not less than 1 MPa (10 bar) (gauge pressure). Pressure receptacles may not be equipped with any pressure relief device. Each pressure receptacle containing a toxic by inhalation liquid with an LC less than or equal to 200 mL m3 (ppm) shall be closed with a plug or valve / conforming to the following: (a) Each plug or valve shall have a taper-threaded connection directly to the pressure receptacle and be capable of withstanding the test pressure of the pressure receptacle without damage or leakage; (b) Each valve shall be of the packless type with non-perforated diaphragm, except that, for corrosive materials, a valve may be of the packed type with an assembly made gas-tight by means of a seal cap with gasket joint attached to the valve body or the pressure receptacle to prevent loss of material through or past the packing; (c) Each valve outlet shall be sealed by a threaded cap or threaded solid plug and inert gasket material; (d) The materials of construction for the pressure receptacle, valves, plugs, outlet caps, luting and gaskets shall be compatible with each other and with the lading. Each pressure receptacle with a wall thickness at any point of less than 2.0 mm and each pressure receptacle that does not have fitted valve protection shall be transported in an outer packaging. Pressure receptacles shall not be manifolded or interconnected.

IMDG Code 42-24 · English source text

Stowage and handling codes

Segregation codes

SG63

Source pages and references

Check original English pages and footnotes ↗ · official PDF 494–494

Stow “separated longitudinally by an intervening complete compartment or hold from” class 1.

IMDG Code 42-24 · English source text

Labels and marks

Reference preview for Entry 1 · Packing group I. Confirm the cargo classification and any conditions in the special provisions.

Toxic substance 6.1
Toxic substance 6.1
Flammable liquid 3
Flammable liquid 3
Marine pollutant mark
Marine pollutant mark

Explore this class