IMDG Code 42-24 · Dangerous Goods List

Open interactive lookup ↗

UN3496BATTERIES, NICKEL-METAL HYDRIDE

English proper shipping name · Check the cargo and applicable provisions before shipment.

Class9
Packing groupNot assigned in this entry
EmSF-A, S-I

Dangerous Goods List entries

The comparison below lists all entries. Expanded provisions and the label preview on this page apply to Entry 1.

Compare all 1 DGL entry

Entry 1

BATTERIES, NICKEL-METAL HYDRIDE

Class
9
Subsidiary risk / reference
Not listed
Packing group
Not assigned in this entry
Marine pollutant entry
Not listed; check the cargo classification
Limited quantities
0
Excepted quantities
E0
Packing instruction
See SP963
Special provisions
117 963
Special packing provision
Not listed
IBC instruction
IBC08
IBC special provisions
Not listed
Portable tank / bulk container codes
Not listed
Tank special provisions
Not listed
EmS
F-A, S-I
Stowage and handling
Category A SW1 Category A SW1
Segregation
Not listed in this DGL field
Properties and observations · source text
Nickel-metal hydride cells or batteries packed with or contained in equipment and nickel-metal hydride button cells are not subject to the provisions of this Code.

IBC instructions

IBC08

Source pages and references

Check original English pages and footnotes ↗ · official PDF 232–232

IBC08 The following IBCs are authorized, provided the general provisions of 4.1.1, 4.1.2 and 4.1.3 are met: Metal (11A, 11B, 11N, 21A, 21B, 21N, 31A, 31B and 31N); Rigid plastics (11H1, 11H2, 21H1, 21H2, 31H1 and 31H2); Composite (11HZ1, 11HZ2, 21HZ1, 21HZ2 and 31HZ1); Fibreboard (11G); Wooden (11C, 11D and 11F); Flexible (13H1, 13H2, 13H3, 13H4, 13H5, 13L1, 13L2, 13L3, 13L4, 13M1 or 13M2). Additional provisions: Where the solid may become liquid during transport see 4.1.3.4. Special packing provisions: B3 Flexible IBCs shall be sift-proof and water-resistant or shall be fitted with a sift-proof and water-resistant liner. B4 Flexible, fibreboard or wooden IBCs shall be sift-proof and water-resistant or shall be fitted with a sift-proof and water-resistant liner. B6 For UN Nos. 1327, 1363, 1364, 1365, 1386, 1408, 1841, 2211, 2217, 2793 and 3314, IBCs are not required to meet the IBC testing provisions of chapter 6.5. B21 For solid substances in IBCs other than metal or rigid plastics IBCs, the IBCs shall be carried in closed cargo transport units or in freight containers/vehicles, which shall have rigid sides or fences at least to the height of the IBC.

IMDG Code 42-24 · English source text

Special provisions

SP 963

Source pages and references

Check original English pages and footnotes ↗ · official PDF 782–783

Nickel-metal hydride cells or batteries packed with or contained in equipment and nickel-metal hydride button cells are not subject to the provisions of this Code. All other nickel-metal hydride cells or batteries shall be securely packed and protected from short circuit. They are not subject to other provisions of this Code provided that they are loaded in a cargo transport unit in a total quantity of less than 100 kg gross mass. When loaded in a cargo transport unit in a total quantity of 100 kg gross mass or more, they are not subject to other provisions of this Code except those of 5.4.1, 5.4.3 and columns 16a and 16b of the Dangerous Goods List in chapter 3.2.

IMDG Code 42-24 · English source text

Stowage and handling codes

Labels and marks

Reference preview for Entry 1. Confirm the cargo classification and any conditions in the special provisions.

Miscellaneous 9
Miscellaneous 9

Explore this class